A minimum of two WCs should be provided in public buildings, so that one may act as a reserve if the other fails. Washbasins are generally provided in equal numbers to WCs with one for every five urinals.
The requirement for sanitary facilities such as WC, Wash basin and Urinal for various building types are provided below:
Building Type: OFFICES & SHOPS (when no urinals are provided)
|
|
No. of persons
|
No. of WCs and Basins
|
Up to 15
|
1
|
16-30
|
2
|
31-50
|
3
|
51-75
|
4
|
76-100
|
5
|
Over 100
|
1 extra for each additional 25
|
Building Type: OFFICES & SHOPS (when urinals are provided)
|
|
No. of persons
|
No. of WCs and Basins
|
Up to 20
|
1
|
21-45
|
2
|
46-75
|
3
|
76-100
|
4
|
Over 100
|
1 extra for each additional 25
|
Building Type: Factories
|
|
No. of persons
|
No. of WCs and Basins
|
For every 25
|
1
|
No. of Washbasins
|
|
For every 20
|
1 (for clean processes)
|
For every 10
|
1 (for dirty processes)
|
For every 5
|
1 (for injurious processes)
|
No specific requirement for
urinals; may follow the relationship mentioned above i.e. five urinals
for every WC.
|
Building Type: Restaurants
|
|||
Male
|
Female
|
||
No. of persons
|
No. of WCs and Basins
|
No. of persons
|
No. of WCs and Basins
|
Up to 400
|
1 per 100
|
Up to 200
|
2 per 100
|
Over 400
|
1 extra for each additional 250 or part thereof
|
Over 200
|
1 extra for each additional 100 or part thereof
|
No. of persons
|
No. of Urinals
|
No. of persons
|
No. of Urinals
|
For every 25
|
1
|
-
|
-
|
No. of persons
|
No. of Wash Basins
|
No. of persons
|
No. of Wash Basins
|
-
|
1 per WC or 1 per 5 Urinals
|
-
|
1 per 2 WCs
|
Building Type: Concert Halls, Theatres & other Auditoriums
|
|||
Male
|
Female
|
||
No. of persons
|
No. of WCs and Basins
|
No. of persons
|
No. of WCs and Basins
|
Up to 250
|
1
|
Up to 50
|
2
|
Over 250
|
1 extra for each additional 500 or part thereof
|
Over 50-100
|
1 extra for each additional 40 or part thereof
|
No. of persons
|
No. of Urinals
|
No. of persons
|
No. of Urinals
|
Up to 100
|
2
|
-
|
-
|
Over 100
|
1 extra for each additional 80 or part thereof
|
-
|
-
|
Building Type: Cinemas
|
|||
Male
|
Female
|
||
No. of persons
|
No. of WCs and Basins
|
No. of persons
|
No. of WCs and Basins
|
Up to 250
|
1
|
Up to 75
|
2
|
Over 250
|
1 extra for each additional 500 or part thereof
|
Over 76-100
|
3
|
Over 100
|
1 extra for each additional 80 or part thereof
|
||
No. of persons
|
No. of Urinals
|
No. of persons
|
No. of Urinals
|
Up to 200
|
2
|
-
|
-
|
Over 200
|
1 extra for each additional 100 or part thereof
|
-
|
-
|
No comments: